Product
position

ZT802 UL TRASONIC DETECTOR

0.00
0.00
  


PRODUCT FEATURES

      Concrete structure internal defects and crack depth detection, homogeneity, damage layer  thickness detection

      Concrete strength testing

      Concrete pile integrity testing (manual)

      Concrete thickness inspection

 

 

MAIN TECHNICAL INDICATORS

    Host: Dedicated microcomputer system

    Reading range when sound: 032Kμs

    Acoustic reading accuracy: ±0.05μs

    Amplitude measurement reading range: 0~138dB

    Gain accuracy: 3%

    Amplifier bandwidth: 5 kHz -300 kHz

    Emission voltage: 250, 500, 1000V adjustable

    Sampling period: 0.05, 0.1, 0.2, 0.4, 0.8, 1.6, 3.2, 6.4μs adjustable

    Operation method: button + photoelectric knob

    Trigger mode: signal trigger, external trigger

    Receiver sensitivity: ≤30 μv

    Signal acquisition method: continuous signal, transient signal

    Number of channels: dual channel

    Maximum penetration distance: normal concrete 10m

    Display: 640×480

    Universal interface: Parallel port, USB port

    Operation Software: English

    Power supply mode:

                1. Built-in lithium battery can supply power continuously for 6 hours.

                2. AC: 220V ± 10%; DC: 12V (AC and DC).

                3. external large-capacity battery, can work for 8-10 hours.

    Working temperature: 040°C

    Operating Humidity: ≤80%

    Total weight: 1.8kg

    The whole volume: 250mm×200mm ×100mm


INSTRUMENT CONSTITUTES

       Including: Host, plane transducer, signal line, manual, software, instrument box, etc.